Product details
Siemens 3RW4457-6BC44 SIRIUS Soft Starter — 3RW4457-6BC44
The Siemens SIRIUS 3RW4457-6BC44 is a high-power soft starter for large motors up to 900 kW. It ensures gentle starts, reduced stress, and steady performance. This model is now phased out — the preferred successor is 3RW5556-6HA14.
Quick Highlights
- Rated current: 880 A (standard), 1524 A (inside-delta)
- Power: 500 kW at 400V, up to 900 kW inside-delta
- Voltage range: 200–460 V AC | Control: 230 V AC
- Frequency: 50–60 Hz with ±10% tolerance
- Insulation voltage: 690 V | Pollution degree 3
Technical Information
- Continuous current: 115% at 40°C
- Power loss: about 250 W during operation
- Minimum load: 8% of IM
- Motor current adjustment min: 176 A
- Thermistor protection and external reset available
Mechanical & Mounting
- Dimensions: 510 mm W × 640 mm H × 290 mm D
- Mounting: screw fixing, ±90° rotatable, ±22.5° tilt
- Clearances: top 100 mm, bottom 75 mm, side 5 mm
- Cable length: up to 500 m | Altitude: max 5000 m
- Main circuit: busbar | Control: screw terminals
Performance Features
- Built-in thyristors and bypass contact system
- Supports inside-delta wiring for higher power range
- Integrated motor brake output for quick stops
- Display indicator for quick fault diagnosis
- Excellent overload and device protection
Environmental & Reliability
- Ambient temp: -25°C to +60°C | Storage: up to +80°C
- IP00 open type, for enclosed installations
- Complies with IEC 60947 and IEC 60721 standards
- Durable for harsh transport and operation conditions
- Warranty: 12 months from Powergear X Automation
Shipping & Support
- Ships globally via FedEx, UPS, and DHL
- Each unit tested before dispatch
- Includes detailed wiring and setup guide
- For technical inquiries, contact sales@powergearx.com
- WhatsApp support: +86 18030005825
Five Professional FAQs
- Q: Can this soft starter replace the 3RW5556-6HA14 directly?
A: It can operate similarly but the 3RW5 offers higher efficiency and better monitoring. - Q: What’s the main difference between standard and inside-delta setup?
A: Inside-delta reduces current per line and allows larger motor power with the same frame size. - Q: How should I manage heat at 880A continuous load?
A: Keep clearance space, ensure airflow, and check terminal torque every 6 months. - Q: How do I test motor protection before startup?
A: Simulate overload by adjusting current limit; verify trip timing under control voltage. - Q: Any tip for long cable installation up to 500m?
A: Use shielded power cables, proper grounding, and verify voltage drop below 3%.