Product details
Bently Nevada 3500/61-05-00 Temperature Monitor
The 3500/61-05-00 monitors up to 6 RTD or thermocouple inputs. This temperature monitor provides precise measurements with recorder outputs. It features non-isolated I/O modules with internal barriers for industrial use.
Product Identification & Features
- Manufacturer: Bently Nevada
- Model: 3500/61-05-00
- Type: Temperature Monitor with Recorder Outputs
- Input Channels: 1 to 6 RTD/TC signals
- Power Consumption: 9 watts nominal
- Made in: USA
- Warranty: 12 Months
Temperature Sensor Compatibility
- Thermocouple Type E: -100°C to +1000°C
- Thermocouple Type J: -18°C to +760°C
- Thermocouple Type K: -18°C to +1370°C
- Thermocouple Type T: -160°C to +400°C
- Platinum RTD (100Ω): -200°C to +850°C
- Nickel RTD (120Ω): -80°C to +260°C
- Copper RTD (10Ω): -100°C to +260°C
Technical Specifications
- Input Impedance: 10 MΩ per lead
- RTD Current Source: 925 μA ±15
- Recorder Output: 4-20 mA proportional
- Voltage Compliance: 0-12 VDC, 0-600Ω load
- Resolution: 1°C or 1°F for most sensors
- Accuracy: ±1°C to ±3°C depending on configuration
- Alarm Setpoints: Adjustable 0-100% of full scale
System Indicators & Alarms
- OK LED: Shows proper module operation
- TX/RX LED: Indicates system communication
- Bypass LED: Displays bypass mode status
- Alert Delay: 1-60 seconds in 1-second steps
- Danger Delay: 1-60 seconds in 0.5-second steps
- Alarm Accuracy: Within 0.13% of set value
Environmental & Physical Details
- Operating Temperature: -30°C to +65°C
- Storage Temperature: -40°C to +85°C
- Monitor Dimensions: 241mm x 24mm x 242mm
- Monitor Weight: 0.91 kg (2.0 lb)
- I/O Module Dimensions: 241mm x 24mm x 99mm
- Rack Space: 1 front slot + 1 rear slot
Shipping & Support
- Shipping Carriers: FedEx, UPS, DHL
- Package Condition: New & Original
- Delivery: Worldwide Express Available
- Support: Technical Assistance Provided
Frequently Asked Questions
- How many temperature sensors can connect?
The monitor supports up to 6 RTD or thermocouple inputs simultaneously.
- What is the power requirement?
It consumes 9 watts nominal power during normal operation.
- Does it work with platinum RTDs?
Yes, it supports 100Ω platinum RTDs with 0.00385 alpha coefficient.
- What recorder outputs are available?
It provides 4-20 mA current outputs proportional to measured values.
- Can I set custom alarm delays?
Yes, alert delays from 1-60 seconds and danger delays in 0.5-second steps.
Contact our experts: sales@powergearx.com or WhatsApp +86 18030005825
Copyright © 2025 Powergear X Automation Limited. All rights reserved.
Original Source: https://www.powergearx.com/
Partner: Ubest Automation Limited















There are no reviews yet.